- What are some basic requirements for the Respiratory Protection Program?
-
Program Manager appointed in writting by CO or OIC.
PPE will be provided by Navy.
Fit testing and medically qualified to wear the respirator. - What is the goal of the Hearing Conservation Program?
- To prevent occupational hearing loss.
- What are some basic requirements of the Hearing Conservation Program?
-
Identify potential noise hazards.
Provide PPE.
Provide training on the program. - If an area is posted as having an eye hazard what should you do?
- Wear the appropriate PPE.
- When should eyewash stations be provided?
- Where running water is unavailable.
- What does the term "warning" mean?
- That the potential to cause injury or death is present if the procedure is not followed.
- What term is defined as being optional?
- May
- What does the term "caution" mean?
- That damaged equipment may result if procedures are not followed.
- What does the term "note" imply?
- An operating procedure, practice or condition that is essential to emphasize.
- What term is used if a procedure is mandatory?
- Shall
- What does the term "will" indicate?
- Futurity. Does not imply any degree of requirement for a procedure.
- How are portable fire extinguisher classified?
- According to the type of fire they are designed to fight.
- Where should portable fire extinguishers be placed?
- In normal paths of travel.
- How should fire lanes be maintained?
-
Clearly marked.
Kept clear or obstructions. - How far away should open flames and smoking be kept from parked A/C and hanger bays?
- 50 feet.
- When should an A/C be grounded?
- During all maintenance evolutions.
- Do tie down chains provide adequate grounding for the A/C?
- No.
- Should A/C be LOXed in inclimate weather?
- No
- The sides on a drip pan should be how high and in what condition when being used aroung LOX?
-
6 inches.
Completely clean..NO CONTAMINENTS! - When draining LOX how many qualified personnel should be present?
- 2
- How many LOX converters can be serviced at one time?
- 2
- What type LOX should always be used?
- MIL-O-27210 Type 2.
- What type of coveralls must be worn when servicing LOX?
- Cuffless.
- If you are involved with a spill of LOX and get it on you what should you do?
- Quickly thaw the exposed area by immersion or at least bathing with large amounts of water.
- After a rapid thaw what should you do?
- Wrap the exposed area loosely and seek medical attention.
- Before filling the LOX converter what should you do?
- Check the safety wire, relief valve and pressure closing valve for security.
- What is more dangerous, LOX or Gaseous Oxygen?
- Gaseous Oxygen.
- When working with Gaseous Oxygen what kind should be used?
- MIL-2710, TYPE 2.
- What can you lubricate oxygen valves with when working on a Gaseous Oxygen System?
-
Type 3 Krytox.
Type 3 Triolube 16. - When using Gaseous Oxygen when can an explosion occur?
- Any time dirt, grease, oil, comes in contact with the Gaseous Oxygen.
- When refueling do the Main Gear doors have to be opened or closed?
- Closed.
- What are some basic precautions to be used when refueling an A/C?
-
Ground the A/C and the resupply unit.
Make sure your getting the right type of fuel.
Do not use any electronic equipment unless otherwise specified. - When you have an open fuel cell what requirements should all portable electrical equipment and connections meet?
- National Electrical Code for Class, 1 Division 1, Group D Hazardous Locations.
- At least how many fully charged fire extinguishers must be present when there is an open fuel cell?
- 2
- Who gives approval to open a fuel cell and upon the location?
-
Maintenance Officer.
Fire Marshall.
Safety Officer. - If exhaust purge is used how much more room is needed to open a fuel cell?
- 50 feet.
- When a fuel cell has been opened how must the area be posted?
- "DANGER, OPEN FUEL TANKS, UNAUTHORIZED PERSONNEL KEEP OUT"