MOD I TECH
Terms
undefined, object
copy deck
- bourdon gauge measures?
- inlet pressure
- 3 indications of 02 therapy
- increase hr, wob and pulmonay hypertension
- 5 causes of arterial hypoxemia
- low ambient 02, v/q mismatch,shunt, diffusion defect, hypoventilation
- 4 types of tissue hypoxia
- anemic, stagnant or circulatory, histoxic (cynaide poisoning), hypoxemic (hyopoxic or demand)
- 4 toxic effects of high dose o2 therapy
-
alveolar wall edema
pulmonary fibrosis
hyaline membrane formation
death of type II aveloar cells - types of evalutation procedures for o2 therapy effectiveness (pt eval)
- color, wob, posture
- symptoms of acute hypoxemia
- dyspnea, tachypnea, tachycardia (1st response of the body to hypoxemia)
- symptoms of chronic hypoxemia
- fatigue, polycythemia
- % of o2 in heli-ox mixture
- 20%
- heli-ox mixture % and factor
-
20% 80% factor 1.8 or
30% 70% factor 1.6 - indications for carbon dioxide theapy
- atelectasis and hiccups, cva (stoke), retinopathy
- maxiium concentration of co2 tha should be used in co2/o2 mixture
-
10% of CO2
90% o2 to 10% co2 - maximum time for co2/o2 treatment
- 10 min
- what should be monitore during co2/o2 treatment
- hr, rr, bp
- adverse side effects of co2/o2 therapy
- hypotension,tachycardia, tachyphnea
- rational for HBO (hyperbaric oxygen chambers)
- hyperoxygenation
- 2 indications for transtracheal oxygen therapy
- lower 02 flow (higher sats),less dilution from room air
- characteristics of high flow system
- meets all pt inspiratory demands. maintain fixed fio2 uneffected by rr,fixed pformance
- characteristics of low flow sys
- o2 flow rate no greate than 6-10 lpm, perforamance varies from breath to breath,additional flow provided by inhaled room air
-
Ve is determined?
ve is minutie ventilation -
vt x rr
tital volume x respiratory rate - 4 hazards assoc with o2 therapy
- o2 toxicity, hypoventilation, absorption atelectasis,dyhydration
- name high flow systems??
- air entrainment masks aka venturi mask,
- name 5 low flow systems
- nasal oxygen cannula, catheter,simple mask,partial rebreather,non rebreather
- why important to keep flow of a simple mask at min of 5-6 lpm
- flow must wash out the mask and prevent rebreathing of co2
- how is flow is gas adj for non rebreathing mask
- increase flow to make sure bag is inflated at all times
- what does HAFOE mean
- hig air flow oxygen enrichment
- 3 factors that change fio2 on the venturi mask
-
jet size
entrainment port size and obstruction of fio2 ports(back pressure) - entrainment ratio of air to oxygen for 24%
- 25:1
- entrainment ratio of air to oxygen for 28%
- 10:1
- entrainment ratio of air to oxygen for 35%
- 5:1
- entrainment ratio of air to oxygen for 40%
- 3:1
- entrainment ratio of air to oxygen for 50%
- 1.7:1
- entrainment ratio of air to oxygen for 60%
- 1:1
- factors controlled by oxygen enclosure
- temp,ox concentration (fio2)and humidity
- croup tent advantages
- good way to administer o2 to pediatric pts
- croup tent disadvantages
- frequent need toopen tent for pt care make fio2 hard to keep constant
- oxy hood advantages
- leave pt body accessible for medical care procedures
- reg agency reponsible for quality and purity of med gaSes like o2
-
FDA
FOOD DRUG ADMIN - REG AGENCY FOR CYLINDER CONSTRUCTION
-
DOT
DEPT OF TRANS - TEST ALUMINIUM CYLINDERS HOW OFTEN
- 5 YEARS
- TEST STEEL SYLINDERS HOW OFTEN
- 10 YEARS
- REG AGENY FOR TANK SAFETY SYS
-
CGA
COMPRESSED GAS ASSOC - TANK COLOR FOR OXYGEN
- GREEN
- TANK COLOR FOR AIR
- YELLOW
- TANK COLOR FOR CO2
- GRAY
- TANK COLOR FOR HELIUM
- BROWN
- TANK COLOR FOR NITROUS OXIDE
- BLUE
- PURPOSE FOR CHECK VALVES AND ZONE VALVES
- ISOLATE SPECIFIC AREA IN CASE OF FIRE, MAINTANCE OR CONSTRUCTION
- HOW MUCH GAS DOES A BULK SYS CONTAIN
- GREATER THAN 20,000 CU FT
- REG AGENCY FOR INSTALLATION OF LIQUID GAS SYS
- ASME-AMERICAN SOCIETY OF MECHANICAL ENGINEERS
-
advantage of bourdon gauge
disadavantage -
accurate in any position
doesn't see flow obstruction gauge remains the same - what does PISS stand for and what are the following combinations for o2 and air
-
pin index safety system
o2 2:5
air 1:5 - reg agency for oxygen purity, dispenation?
-
usp
united states pharmacopeia - purity of med o2
- 99.0%
- recommends storage of gas cylinders?
-
NFPA
NATIONAL FIRE PROTECTION AGENCY - E CYLIDER IS LEAKING NITROUS OXIDE WHAT DO YOU DO?
- REPLACE WASHER BETWEEN REGULATOR AND TANK AND TIGHTEN THE CONNECTION
- WHY CRACK CYLINDER
- DEMONSTRATE PRESSURE AND HELP REMOVE DEBRIS FOR VALVE OUTLET
- PRESSURE RELIEF VALVE PREVENTS
- EXCESSIVE PRESSURE FOR BUILDING UP INSIDE THE CYLINDER AND TANK RUPTURE ON
- OXYGEN SUPPORTS COMBUSTION AND IS NONFLAMMABLE T OR F
- TRUE
- COMMON METHODE OF O2 PRODUCTION FOR COMMERICAL PRODUCTION
- THE JOULE-KELVIN METHODE
- REASONS HELIUM IS A VALUEABLE THERAPEUTIC GAS?
- LOW DENSITY,CHEMICAL INERTNESS, BEING NONFLAMMABLE
- 3 TYPES OF AIR COMPRESSORS?
-
PISTON
DIAPHRAGM
ROTARY OF CENTRIFUGAL - WHAT IS AN AIR COMPRESSOR
- PRODUCE AIR TO MIX WITH O2 TO DECREASE ITS CONCENTRATION
- WORKING PRESSURE OF AIR COMPRESSOR
- 50 PSI
-
JUST THE FACTS
PISTON COMPRESSOR
ELECTRICALLY DRIVEN
POWERS VENTILATORS
PROVIDES LRG AMTS OF AIR -
JUST THE FACTS
DIAPHRAM
ELECTRICALY DRIVEN
DIAAPHRAM USED INSTEAD OF PISTON, PROVIDES SM AMTS OF AIR, POWERS SMALL NEBS -
JUST THE FACTS
ROTARY CENRIFUGAL
ELECTRICALLY POWERED
PUSHED AIR WITH ROTATION PROPELLORS,WATER COOLS IT AND REDUCES WEAR, HAS WATER FILTER FOR CONDENSED AIR, LARGE VERSIONS POWERS HOPITALS - THIS IS ONLY A TEST! DON'T FREAK OUT SANDY! YOU WILL SCORE AN A!!!!!!
- WHAT IS A CONCENTRATOR
- DEVICE THAT SEPERATES 02 FROM THE NITROGEN IN ROOM AIR. INCREASE THE CONCENTRATION OF O2
- 2 TYPES OF CONCENTRATORS
- MOLECULAR SIEVE AND MEMBRANE
- HOW DOES THE MOLECULAR SIEVE CONCENTRATOR WORK?
- PUMP COMPRESS AIR, DELIVERS IT TO 1 OR 2 SIEVE BEDS WITH ZEOLITE PELLETS. THE PELLET ABSORB NITROGEN AND LEAVE 02 TO PASS THRU. O2 STORED IN RESERVIOR. SWITHES BACK N FORTH TO PURGE NITOGEN FROM SIEVE BEFD
- JTF:MOLECULE SIEVE CONCENTRATOR IS MOST COMMON AND DEPENDS ON AIR FLOW
-
JTF:MOLECULAR SIEVE CONCEN
1-2L/MIN FIO2 IS 90-95%
2-5LPM 80-90%
10LPM THE FIO2 IS 50%
MOrE FLOW=LESS FIO2 - MEMBRANE CONCENTRATOR WORKS HOW
- THIN PERMEABLE PLASTIC POLMER MEMRANE SEPERATES THE 02 FROM ROOM AIR. GAS DIFUSES AT DIFFERENT RATES 02 AND H20 ARE FASTER THAN NITROGEN (N2)
-
JTF:MEMBRANE CONCENTRATORS
1-10 LPM IS 40% FIO2
REMAINS STABLE DESPITE FLOW - SANDY YOU RULE!
-
WHAT KIND OF CONCENTATOR WOULD YOU FIND IN A HOSPITAL
AND WHAT % OF FIO2 - A LARGE CONCENT USES MOLECULAR SIEVE PRINC PROVIDEDS 92-95% FIO2
- ADV AND DISAVANTAGES OR COMPRESSORS
-
DIS:NEED BACK UP TANKS FOR PWR FAILURE, SM CONCENTOR CAN'T PWR HIGH PRESSURE DEVICES (50 PSI), NOISY,$$,MAINTENCE OFTEN,
ADVANTAGES: USEFUL FOR HOME PTS ON 02, COST EFFECTIVE AT LOW LITER FLOWS - 1 CU FT OF LOX EXPANDS TO ? GASEOUS CU FT?
- 862
- WITH LOX 1 LITER WEIGHTS ? LBS
- 2.5
- HOW IS LIQ OX PRODUCED
- AIR IS FILTERED, COOLED TO FREEZING,DIVIDED, COMPRESSED,THEN WARMED TO BOIL OFF OTHER GASES
- LOX ADV AND DIS
-
ADV: SHIPPING IS LESS $ THAN GAS CYL,LESS SPACE, PROVIDES LRG AMT OF O2,SMALLER CAN BE FILLED BY LRGER
DIS:LOSS OF 02 DUE TO VENTING
LOW TEMP IS HAZARD (BURNS) - REG AGENCY OF STRUCTURAL SPECS OF LOX BULK SYSTEM
-
NFPA
NATIONAL FIRE PROTECTION AGENCY - REG AGENCY FOR CONSTRUCTION OF LOX BULK SYS
-
ASME
AMERICAN SOC MECH ENGINEERS -
JTF: LOX BULK SYS
50 FT FROM COMBUSTI STRUCTURE
25 FROM FIRE RESIST STUCTURE
50 FROM PTS AND 10 FROM SIDE WALKS -
JTF: LOX BULK SYS
HAS 2 ALARMS AND 24 HOUR COVERAGE -
JTF: PIPING SYSTEMS
SUPPLied FROM TANK BANK OR LOX BULK OR BOTH, CYL BANK HAVE CK VAVLES,NEED BACK UP SYSTEM MUST LAST 24HRS -
JTF:PIPING SYSTEM
REGULATOR REDUCED TO 50PSI
MADE OF COPPER,SEEMLESS, OR BRASS w COPPER,EACH FL HASE SHUT OFF ZONE VALVE - REG AGENCY FOR PIPE SYSTEM
- NFPA
- TYPES OF QUICK CONNECT STATATION OUTLETS
-
OHIO DIAMOND (BIG MIDDLE NIPPLE 2 LITTLE ONES)
SCHRADER (HEXI)
NCG (1 BIG NIPPLE 1 MEDIUM BELOW) - 2 TYPES OF STATION OUTLETS
- DISS AND QUICK CONNECT
-
JTF: DISS STATION OUTLET
FEMALE FITTING GOES OVER OPENING TILL CONTACTS PLUNGER TILL HITS STEM ALLOWING GAS TO FLOW
PRESSURE LESS THAN 200 PSI -
JTF: QUICK CONNECT
MUST HAVE GAS LABEL
5 FT FROM FL
USES PLUNGER - 3 AA CYLINDER MARKING MEANS?
- STEEL
- 3AL CYL MARKING MEANS
- ALUMINIUM
- STAR ON CYL MARKING MEANS
- STEEL CYL CAN GO FOR 10 YRS W/O TESTING
- + AFTER DATE CYL MARKING MEANS
- PASSED
- WORKING PRESSURE OR SVC P ON A CYL IS INDICATED ON SHOULDER AND CAN BE OVER FILLED BY ? %
- 10%
- MARKING ON A CYLINDER
-
DOT (REG AGENCY)
3AA OR 3AL (MATERIAL MADE OF)
2015 (SVC PRESSURE)
HYROSTATIC TEST DATE
SER #
OWNERSHIP MARK AND COLOR CODE -
LARGE CYL REGULATOR ATTACHMENT
(SPECIAL THREADS) -
ASSS
AMER STANDARD SAFETY SYS - SMALL CYL REGULATOR ATTACHMENT
-
PISS
PIN INDEX SAFETY SYTEM -
H CYLINDER TANK FACTS?
L OF 02 AND CU FT
TANK FACTOR -
H CYL CONTAINS 6900 L OF O2 AND 244 CU FT
TANK FACTOR 3.14 -
E CYLINDER TANK FACTS?
L OF 02 AND CU FT
TANK FACTOR -
622 L OF 02 AND 22 CU FT
TANK FACTOR .28 -
JTF: CYL VALVE
DIRECT ACTING:VALVE OPEN AND CLOSES DIRECTLY
INDIRECT ACTIONG:DIAPHRAGM OPENS OR CLOSES THE VALVE SEAT -
JTF: REDUCING VALVE
REDUCES THE P FROM CLY TO WORKING P IN STAGES,
EACH STAGE HAS OWN P RELIEF VALVE - WHAT IS A REGULATOR
- WHEN A FLOWMETER AND A REDUCING VALVE ARE JOINED TOGETHER
- 2 TYPES OF FLOW METERS
-
THORP TUBE
AND BOURDON -
JTF: THORP TUBE FLOW METER
COMPENSATED IS ACCURATE EVEN IN BACK PRESSURE
DISadv: MUST BE UPRIGHT -
JTF:BOURDON GAUGE FLOW METER
RESPONDS TO P BUT IS CALIBRATE TO READ FLOW.
INACURRATE WITH BACK PRESSURE - PROPORTIONER BLENDER DO WHAT?
-
MIX AIR AND O2
ALLOW PRECISE O2 TO BE DELIVER TO PT
NEED 50PSI OF O2 AND 50 OF AIR
STABEL 50 PSI SOURCE - HOW DOES A PROPORTIONER BLENDER WORK?
- AiR AnD O2 ENTER CHAMBER ON OPPOSITE SIDES OF DIAPHRAM. DIAPHPRAM BALANCES PRESSURES W/ A REGULATOR. GAS PASSES THRU PROPORTING VALVE. IF GAS P DROPS ALAMS SOUNDS.
- ADV , DISADV OF BLENDERS
-
ADV: CAPACITY TO DELIVER GAS AT FLOWS EXCEEDING 100 LPM
DISADV:$$ COMPARED TO 2 FLOW METERS, VARIATION IN INLET P WILLSOUND ALARM,DEBRIS KEEPS CK VALVE FROM SEATING AND DIAPHRAM MOVING PROPERLY - IF NO BLENDER USE 2 FLOWMETERS AND CALCULATE FLOW AND FIO2 HOW?
- FIO2=(AIR FLOWx21)+(O2 FLOW X 100)/TOTAL FLOW
- WHAT DO YOU NEED TO KNOW TO DESPENSE O2
-
DR ORDER
TYPE OF EQUIP
FREQUENCY(CONTIUNOUS OR PRN)
LITER FLOW OR FIO2 - PT REQUIREMENT FOR LOW FLOW device
-
PT SHOULD HAVE
AVG Vt, RR and specific FIO2 SHOULD NOT BE Required - anatomic reservoir in adults is
- 1 cc per lb of ideal body weight about 150 cc
- the anatomic reservoir is filled at what % of o2 between end of expiration and beginnin of inspiration
- 100% o2
-
cannula
flow lpm? -
6-8 lpm
dries nasal mucosa at 6 lpm
anatomic resevior full at 6 lpm - cannula adv and disadvantages
-
adv:inexpensive,well tolerated, easy to be mobile
disadv:easily dislodged, drying, FIO2 varies - catheter advatages and disadv
-
adv:good for restless pt
disadv:easily plugged,overinstertion causes gastric insufflation
can't use w/ nasal obstuction -
simple mask
lpm?
fio2? - 6-10 lpm provide 35 -60%
- nasal cannula: fio2 after 20% is increase by ??% for every lpm of flow
- 4%
- remove catheter how often
- every 8 hrs
- simple mask adv and disadv
-
advantages higher fio2, use w pts after nasal surgery
disadv: more $$,can't eat or have oral care,closterphobic -
partial rebreather
lpm and
fio2 ?? -
8-10 lpm enough to keep bag inflated!!!
35-60% -
non rebreather
lpm and fio2? -
12-15 lpm enough to keep bag inflated!!
60-100% on a good day 100% WITH PERFECT FIT -
JTF:NON REBREATHER
ONE PORT OPEN ON SIDE
ONE WAY VALVE BETWEEN MASK AND BAG -
JTF:NON REBREATHER MASK
POOR FIT CAN USE MASK AND CANNULA - ? RANGE % OF LOW O2 CONCENTRATION?
- 21%-39% LOW
- ? RANGE % OF MODERATE O2 CONCENTRATION?
- 40-59% MODERATE
- ? RANGE % OF HIGH O2 CONCENTRATION?
- GREATER THAN 60%